Pressure transmitter VB83

Type VB83

Pressure transmitter with metallic measuring cell

 

Application Area

For measurement of liquids and viscous products with high process pressure.
 
 

The pressure transmitter VB83 is a pressure transmitter for pressure measurement of gases, vapours and liquids in all industries. The VEGABAR 83 offers special advantages in applications with high pressures. The simple connection of VEGABAR series 80 sensors as electronic differential pressure opens new possibilities for the measurement of differential pressures.

 

 

Your benefit

  • Maximum dependability and safety through proven technology
  • High reliability through vacuum resistant version
  • Universal use due to welded measuring cell

 

Specifications Technique
Measuring range - Distance -
Measuring range - Pressure -1...1000 bar
Process temperature -40...200 °C
Process pressure -1...1000 bar
Accuracy 0.075 %
Materials, wetted parts
  • 316L
  • Alloy C22 (2.4602)
  • 316Ti (1.4571)
  • Alloy C4 (2.4610)
Threaded connection ≥ G½, ≥ ½ NPT
Flange connection ≥ DN25, ≥ 1"
Hygienic fittings
  • Clamp ≥ 1" - DIN32676, ISO2852
  • Slotted nut ≥ DN25 - DIN 11851
  • Varivent ≥ DN25
  • hygienic fitting with tension flange DN32
  • hygienic flange connection ≥ DN50 DIN11864-2
  • SMS 1145 DN51
  • SMS DN38
  • hygienic fittings ≥ DN33 - DIN11864-1-A
  • hyg. collar clamp adapter DN40PN40 DIN 11864-3-A
  • hyg. clamp connection DIN11864-3-A; DN50 Rohr ø53
  • Swagelok VCR screwing
  • Varivent G125
Seal material no media contact
Housing material
  • Plastic
  • Aluminium
  • Stainless steel (precision casting)
  • Stainless steel (electropolished)
Protection rating
  • IP66/IP67
  • IP66/IP68 (1 bar)
  • IP68 (0,2 bar)
  • IP66/IP68 (25 bar)
  • IP69K
Output
  • Profibus PA
  • Foundation Fieldbus
  • 4...20 mA
  • 4...20 mA/HART - two-wire
  • Modbus
  • Secondary electronics for electronic differential pressure
Ambient temperature -40...80 °C

  

Approvals  
Scope
  • ATEX/Europe
  • CSA/Canada
  • FM/USA
  • EAC (GOST)/Belarus
  • EAC (GOST)/Russia
  • IEC/worldwide
  • INMETRO/Brazil
  • CCOE/India
  • CSA/USA and Canada
Explosion protection
  • Intrinsic safety "i"
  • Flameproof enclosure "d"
  • Dust explosion protection through housing "t"
Foodstuffs/Pharma
  • 3A
  • EHEDG
  • FDA
  • EG1935/2004
Ship approval
  • ABS
  • BV
  • CCS
  • DNV
  • GL
  • LR
  • RINA
Overfill protection
  • WHG
  • VLAREM II
SIL qualification SIL2

 

Display & adjustment  
Adjustment
  • PLICSCOM
  • PC, PACTware and DTM
  • HART-Communicator
  • Software (e.g. AMS™, PDM)
Indication
  • Display/adjustment module PLICSCOM
  • VEGADIS 81
  • VEGADIS 82

Pressure Transmitter With Metallic Measuring Cell 1

Pressure Transmitter With Metallic Measuring Cell 2