Digital strain gauge and standard signal amplifier

Type E-ADLM-NS

 

Description

Besides programming the E-ADLM-HD Digital strain gauge and standard signal amplifier via serial interface, it is possible with the keys of the display, too.

 

The analog mV/V output signal supplied by the strain gauge sensors is processed by the digital measuring amplifiers and converted into a corresponding output signal.

 

Technical features

  • Input Strain gauge: up to 4 full bridges
  • Input sensitivity: 0,1...5 mV/V
  • Input standard signal: 4...20 mA, 0...10 V
  • Analog output: 4...20 mA / 0...10 V
  • Voltage supply: 24 VDC
  • Resolution: 12 / 14 / 15 / 16 bit
  • Combined error: 0,2% of end scale value
  • Optionally: limit value switch / interface
  • RS232, RS485, Can-Bus, Profibus
  • Degree of protection: IP20
  • Adjustment: via RS232 interface

 

Application

The measuring amplifier is suitable for load/force measuring and has a comfortable configuration. With the output signal it is possible to operate e.g. a large indicator or to evaluate it with a SPS. Among others for use in container terminals, silo works or overhead cranes.