Description
Compact-type Safe PLC suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508). The programming and parameterization is possible by serial interface.
With the integrated functions for digital signal processing like on sensors, control switches or cut-off channels typical safety task can be solved very comfortable.
Safe motion monitoring on highest demands - no problem with SCU. Firmware based on monitoring functions with many field proofed extended functions take care for a simple and transparent realization of any such task.
Technical features
- Compact-type Safe PLC suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
- Safe digital inputs: 14 (inclusive 10 OSSD compatible)
- Safe analog inputs: 2 (4 standard)
- Safe relay outputs: 3 (6 standard)
- Standard outputs: 2
- Pulse outputs (clock): 2 (for cross short circuit detection)
- Supply: 24 VDC
- Operation temperature: 50 °C
- Mounting: Top hat rail
- Option: Interface modules
- Protection: IP20
- Control: Keys for Acknowledge, Start, Reset on front