S-Type push-pull load cells
octogon is one of the leading distributors of high quality and precise weighing technology that is used in many industrial fields. Our extensive range of load cells and force sensors, based on strain gages, impresses with high accuracy, reliability, and a first-class price-performance ratio.
Area of application
S-Type push-pull load cells can be found in weighing equipment for small to medium load ranges up to one ton. The load cell, S-Type C3 is used in hybrid scales, silo scales, tensile force test machines, tank weighing, filling, dosing and mixing systems, crane scales, big bag scales, medical lifter scales and hanging container scales. When used as a force transducer, they can also be found in tensile force test machines or in material fatigue testing systems. They are perfect for pull and push applications.
Features
- Material: Stainless steel
- Capacity: many different capacitys
- Protection class: IP68
- Design: The measuring element is hermetically sealed - Laser welded
- Particularly robust for heavy duty industrial use
- Optional: integrated measuring amplifier (4...20mA, ±10V or 0...10V)
- Optional: integrated IO-Link measuring amplifier
- ATEX, IECEx, CSA
- Optional: calibration ÖNORM EN ISO/IEC 17025
- High temperature: -50°C...+150°C
The load cell, S-Type is made of stainless steel IP68 and particularly suitable for measuring tension and pressure, since it has been awarded protection class IP68. The spring body of the load cell, S-Type is located in the middle bar. This metal piece made of stainless steel deforms under pressure and returns to its original shape when relieved. This deformation process is measured with a strain gage and converted into an electrical signal. The load cell, S-Type can be calibrated in weight or force units.
If you cannot find what you are looking for in the product portfolio below, please do not hesitate to contact us. We are continuously expanding our portfolio and we are sure that we can find a solution for your metrological challenge.
Specifications | Technique |
---|---|
Capacity | 1N - FSA-1 2.5N - FSA-2.5 5N - FSA-5 10N - FSA-10 20N - FSA-20 50N - FSA-50 100N - FSA-100 200N - FSA-200 300N - FSA-300 500N - FSA-500 |
Sensitivity | 2.0±10%mV/V |
Zero balance | ±0.02%F.S. |
Non-linearity | 0.05%F.S. |
Hysteresis | 0.05%F.S. |
Repeatability | 0.05%F.S. |
Creep{30min) | 0.05%F.S. |
Temp.effect on output | 0.05%F.S./10 C |
Temp.effect on zero | 0.05%F.S./10 C |
Input impedance | 350±30Ω |
Output impedance | 350±5Ω |
Insulation | ≥5000M Ω /100VDC |
Recommended excitation | 5V |
Maximum excitation Voltage | 15V |
Compensated temp range | -10∼60°C |
Operating temperature range | -20∼80°C |
Safe load limit | 150%F.S. |
Breaking load | 300%F.S. |
Cable size | ∅ 2 x 4000mm |
Weight approx. | 0.1kg |
Material | Stainless Steel |
IP Class | IP66 |
Cap(N) | A | B | M |
---|---|---|---|
1, 2.5, 5, 10, 20 | 5 | 6.8 | M3 |
50, 100, 200, 300, 500 | 6 | 7.5 | M4 |
Specifications | Technique |
---|---|
Capacity | 50kg - WSD-50 100kg - WSD-100 200kg - WSD-200 500kg - WSD-500 1000kg - WSD-1000 2000kg - WSD-2000 3000kg - WSD-3000 5000kg - WSD-5000 |
Sensitivity | 2.0±0.25%mV/V |
Zero balance | ±0.01%F.S. |
Non-linearity | 0.018%F.S. |
Hysteresis | ±0.018%F.S. |
Repeatability | 0.018%F.S. |
Creep{30min) | 0.024%F.S. |
Temp.effect on output | 0.014%F.S./10 C |
Temp.effect on zero | 0.017%F.S./10 C |
Input impedance | 350±5Ω |
Output impedance | 350±5Ω |
Insulation | ≥5000M Ω /1 OOVDC |
Recommended excitation | 5V |
Maximum excitation Voltage | 15V |
Compensated temp range | -10∼40°C |
Operating temperature range | -30∼70°C |
Safe load limit | 150%F.S. |
Breaking load | 300%F.S. |
Cable size | ∅ 5.4 x 1500mm |
Material | Stainless Steel |
IP Class | IP68 |
Cap(kg) | L | H | W | M |
---|---|---|---|---|
50 | 50.8 | 63.5 | 25.4 | M8 |
100, 200 | 50.8 | 76.2 | 25.4 | M12 |
500 | 57.2 | 87.3 | 31 | M12 |
1000 | 57.2 | 87.3 | 31 | M12 |
2000 | 69.8 | 100 | 36.5 | M24 x 2 |
3000 | 69.8 | 100 | 36.5 | M24 x 2 |
5000 | 76.2 | 114.3 | 36.5 | M24 x2 |
Type | Capacity | Price €, plus VAT |
---|---|---|
WSD-50 | 50 kg | 185,- |
WSD-100 | 100 kg | 185,- |
WSD-200 | 200 kg | 185,- |
WSD-500 | 500 kg | 185,- |
WSD-1000 | 1.000 kg | 185,- |
WSD-2000 | 2.000 kg | 185,- |
WSD-3000 | 3.000 kg | 185,- |
WSD-5000 | 5.000 kg | 215,- |
Specifications | Technique |
---|---|
Capacity | 500N - FSB-500 1000N - FSB-1000 1500N - FSB-1500 2000N - FSB-2000 |
Sensitivity | 2.0±10%mV/V |
Zero balance | ±0.05%F.S. |
Non-linearity | 0.05%F.S. |
Hysteresis | 0.05%F.S. |
Repeatability | 0.05%F.S. |
Creep{30min) | 0.05%F.S. |
Temp.effect on output | 0.025%F.S./10 C |
Temp.effect on zero | 0.025%F.S./10 C |
Input impedance | 385±20Ω |
Output impedance | 350±10Ω |
Insulation | ≥5000M Ω /100VDC |
Recommended excitation | 5V |
Maximum excitation Voltage | 15V |
Compensated temp range | -10∼60°C |
Operating temperature range | -20∼80°C |
Safe load limit | 150%F.S. |
Breaking load | 200%F.S. |
Cable size | ∅ 3 x 4000mm |
Weight approx. | 0.1kg |
Material | Stainless Steel |
IP Class | IP66 |